• Machine Description

    Leak tester speed is synchronized with conveyor. Leak tester will move along with conveyor to test bottle whether there is leakage. If any bottle has leakage, bottle will be automatic rejected at outfeed area.

  • Feature

    l Module base design, fast installation

    l  Apply different bottlewithout change machine structure

    l  With PLC control and HMI touch screen

    l  With air rejecter to reject any defected bottle


  • Machine Parameter

    Item

    Parameter

    Note

    Electricity

    3 phase 5 wires 380V 50HZ or 220V


    Power

    0.3KW


    Air Pressure

    0.6±0.1MPa 


    Air Consumption

    100L/min filteredair


    Applied Bottle size

    Volume between 30ml~15L

    It may required changeover parts

    Leak Test Accuracy

    hole diameter≥0.2mm;

    Accuracy, Failure rate, hole diameter is related to bottle volume

    Accuracy>99.8%

    Leak Test Failure rate<0.1%

    Leak Test Channel

    1~3

    Speed

    TBA

    Size

    As per CAD Drawing

    Weight

    Less than 400kg


EPLT-S Moving Head Leak Tester

Leak tester speed is synchronized with conveyor. Leak tester will move along with conveyor to test bottle whether there is leakage. If any bottle has leakage, bottle will be automatic rejected at outf

扫描二维码

观看产品视频

Call
Product